| We offer a wide variety of Do-It-Yourself electronic goods and services, specializing in Home Alarm Systems. We offer Burglar alarm systems, installation kits, and supplies for the home or office. Let us provide you with the expertise you require, at a price you can afford. |
|
|
|
|
|
Sensaphone FGD1108
|
|
NOW YOU CAN PROTECT YOUR
EQUIPMENT AND PROCESSES EVEN WHEN YOU CAN'T BE THERE. ALERTS YOU IMMEDIATELY IF
PROBLEMS ARISE.
|
|

|
The Sensaphone FGD1108
monitors your computer rooms, equipment centers, offices, or any unattended
facility to detect power failures, temperature extremes, intrusions, water
incursion, sounds such as smoke and burglar alarms, and other conditions of
your choice.
The Sensaphone FGD1108
automatically contacts you by phone at up to eight different phone numbers,
to alert you of unsafe conditions. The system communicates in
voice-synthesized English, and even lets you “listen in” to actual
on-site sounds.
|
|
|
|
| The
versatile Model FGD1108 is designed for programming flexibility. |
| Variable
alarm recognition and “listen-in” time, with alarm
disable, security code access, remote sensing, and other
programming features. |
| Monitors
power, temperature, and other important environmental
conditions to protect computers, equipment, and processes. |
| Automatically
contacts you at up to 8 locations if unsafe conditions occur. |
| Allows
you to contact your system using any telephone, to receive
status reports and listen in to on-site sounds. |
| Helps
you detect problems before they turn into disasters. |
|
|
Accessories
and Sensors |
|
|
|

|
FGD1100 The remote temperature sensor is designed
to monitor air temperature indoors. It features terminal screw
wiring connections, small size, and a convenient wall-mount
housing. The sensor is accurate to ± 1ºF (0.56ºC) and has a
sensing range of -40ºF to 175ºF. Dimensions: 2.5" x
0.75" x 0.75" |
|
|
|

|
FGD0013
WATER DETECTION SENSOR Can be used with all Sensaphone models to
detect the presence of water on a horizontal surface.
Independently powered by internal lithium batteries. Multiple
sensors can be wired in series to a single input. Dimensions:
2.25" x 1.125" x 3.625" |
|
|
|

|
FGD-0027
HUMIDISTAT Can be used with all Sensaphone models to detect too
high or too low a humidity level. Range of the humidistat is 10%
to 60% RH. The sensor causes an alarm when the humidity exceeds
or falls below the set limit. Multiple sensors may be wired to a
single input. Dimensions: 4.125" x 2.75" x 1.5" |
|
|
|

|
FGD0101
WEATHERPROOF TEMPERATURE PROBE These small temperature probes
are good general purpose devices for indoor/outdoor
applications.They include a sensitive temperature element in a
stainless steel housing with a moisture resistant seal. A
convenient mounting clip and 12' of wire are included.The
sensors are accurate to ±1ºF (0.56ºC) and have a sensing
range of -40ºF to 175ºF. Dimensions: 2" long x 0.25"
diameter |
|
|
|
|
|
|
|
Sensaphone
1108 FAQ's
| Q: |
Are
the batteries included? |
| A: |
No. Six
standard “D” size batteries are required to operate
this Sensaphone during power failure. |
|
|
| Q: |
What
conditions can be monitored right out of the box? |
| A: |
Everything
you need to monitor power, temperature and sound are
included with this Sensaphone. The temperature sensor
will report the exact temperature wherever the
Sensaphone is located. To measure the temperature at a
different nearby location, the Remote Temperature Sensor
is available (sold separately). |
|
|
| Q: |
What’s
the difference between 1104 & 1108? |
| A: |
The
Sensaphone 1104 and 1108 are similar in operate. The
1104 allows connection of up to four sensors (including
the temperature sensor which comes with the unit) as
well as calls up to four people or pagers. The 1108
allows attachment of up to eight sensors and calls eight
people or pagers. |
|
|
| Q: |
Can
I run this off a 12V battery? |
| A: |
This
Sensaphone includes a 110VAC power supply which supplies
a controlled low-voltage AC supply to the Sensaphone. If
your requirements demand 12V DC operation, please
contact our Technical Support department for specific
information regarding DC operation of our products. |
|
|
| Q: |
Can
this be used with digital phone line? |
| A: |
No. All
of our Sensaphone products require attachment to a
standard telephone line. Sensaphone systems are not
designed to operated with digital phone systems such as
might be located in a private office. This is because
each telephone system manufacturer operates their
systems differently. Additionally, our systems do not
operate on ISDN networks. |
|
|
| Q: |
Can
this product speak a foreign language? |
| A: |
This
Sensaphone will offer status reports and alarm reports
in English language only. If you require a specific
language, a more advanced Sensaphone may be for you.
Contact one of our Sales Associates for assistance in
determining which Sensaphone will accommodate your
language needs. |
|
|
| Q: |
Can
I install a desktop dialer directly into a greenhouse or
barn? |
| A: |
Yes.
This Sensaphone is ideal for use in just about any
application. However, when using a Sensaphone in any
environment that is subject to moisture, or outdoor
conditions, care should be used when locating the unit.
Often, one of the higher-end Sensaphone models may be
better suited for this environment, which include a NEMA
watertight enclosure. Contact a Sensaphone Sales
Associate to discuss your specific application further. |
|
|
| Q: |
Which
applications are the line seizure models best suited
for? |
| A: |
The
Sensaphone 1104 and 1108 are available in a version that
supports Line Seizure. Line Seizure means that when the
Sensaphone needs to make an important alarm call, it
will hangup (disconnect” anybody else from using the
telephone line so that a clear line is available for use
by the Sensaphone. This is important if you need 100%
ability delivery of the alarm message. But not all
applications require the line seizure model. If you
intend to share the same telephone line that the
Sensaphone is going to use with other systems or people,
you will want to use the line seizure model. The
Sensaphone must be the first ‘device’ on the
telephone line and the other devices plug into the
Sensaphone. To obtain the Sensaphone 1104 with line
seizure, ask for model number FGD-1114. For the 1108,
FGD-1118. If you are unsure if your application requires
line seizure, contact a Sensaphone Sales Associate to
discuss your requirements. |
|
|
| Q: |
What’s
the max length of wire I can use between the dialer and
the sensor? |
| A: |
This
Sensaphone can support sensors as far away as 1,000’.
All that is required is either category-3 (standard
telephone) wire or category-5 (computer wire). You may
also use any wire which is between 22g and 24g. |
|
|
| Q: |
Can
a desktop dialer be used in Europe? |
| A: |
Yes.
Many of our Sensaphone systems can operate in just about
any country. The Desktop models are available with
several power options for 220V 50Hz. |
|
|
| Q: |
Can
Sensaphone share the phoneline with another phone or
device? |
| A: |
Yes. If
you have a telephone answering machine attached to your
telephone line, the Sensaphone can be instructed to
allow you to call into your Sensaphone without having
the answering machine answer the telephone call. |
|
|
| Q: |
Is
there a monthly fee involved? |
| A: |
No.
There are never any monthly fees for monitoring with a
Sensaphone system. With a Sensaphone, you own the
monitoring system and control who and where the any
alert calls go. |
|
|
| Q: |
Do
I need to hire a professional to install? |
| A: |
No. The
Sensaphone Desktop models are very easy to setup and
program. Generally, setup can be completed in as little
as 10 minutes. But if you have special requirements such
as unique wiring needs or special sensors, you may wish
to enlist the assistance of an installer. Just about
anybody whose job is to handle low voltage wiring can
assist in the installation of sensors and wiring. If you
are unsure if your application will require special
installation, contact our Technical Support department
and they can assist you in determining how much
installation may or may not be required. |
|
|
|

|
|
|